CONCRETE REPAIR & STRENGTHENING

Resin Injection & Structural Grouting

Targeted injection and grouting for cracks, voids, anchors and load transfer, without large-scale breakout.

Resin injection into a concrete crack
LOW-IMPACT REPAIR

Targeted repairs that keep the structure intact

Clan delivers specialist resin injection and structural grouting solutions for crack repair, void filling, anchor fixing and load transfer across North West England.

These targeted systems treat internal defects and structural connections without requiring large-scale breakout. Subject to investigation and design confirmation, low-impact injection can preserve existing sound construction, minimise demolition and reduce operational downtime.

Injection ports installed along a concrete crack
RESIN & GROUTING APPLICATIONS

Resin & grouting applications

01

Resin crack injection

Structural problem
A stable crack has reduced continuity or created a defined water path.
Solution
A selected low-viscosity resin fills and bonds the crack, or a flexible resin controls water where specified.
Asset benefit
Treats the defect locally while retaining sound surrounding material.
02

Cementitious grouting

Structural problem
A gap or localised void requires a flowable cement-based material.
Solution
Compatible, often non-shrink grout fills the prepared space.
Asset benefit
Reinstates support or section without rebuilding a wider sound area where conditions allow.
03

Void filling

Structural problem
Confirmed voids exist beneath slabs, behind construction or around existing details.
Solution
Resin or grout is introduced through planned access points to fill the void.
Asset benefit
Can reduce extensive opening-up, demolition, reinstatement and downtime.
04

Structural anchoring

Structural problem
New bars, bolts or components must transfer load into concrete or masonry.
Solution
The specified resin or grout bonds the anchor into a drilled and prepared hole.
Asset benefit
Creates a designed local connection with limited local breakout.
05

Baseplate or bearing grouting

Structural problem
Gaps, uneven bearing or installation tolerances prevent continuous support.
Solution
Structural grout fills the designed bearing area beneath the plate or bearing.
Asset benefit
Supports alignment, stability and reliable load transfer.
DESIGN & SUBSTRATE

What determines system suitability

  • The cause and structural significance of the crack, void or connection.
  • Whether a crack is stable, moving or water-bearing.
  • Substrate material, strength, moisture and contamination.
  • Void size, geometry, access and containment.
Prepared concrete ready for injection works
  • Required bond, compressive strength, flow and load transfer.
  • Injection pressure and the risk of material escaping into adjacent areas.
  • Temperature, curing time and operational constraints.
  • Anchor design, installation depth and any proof-testing requirement.

Injection and flowable grouting can reach suitable defects through small, planned access points. They are targeted construction methods rather than completely non-destructive processes. Drilling, local breakout, containment, monitoring or proof testing may still be required.

TARGETED DELIVERY

From investigation to a recorded, tested repair

01

Investigate

Confirm the crack, void or connection and its structural significance.

02

Select

Choose the resin or grout for the bond, flow and load transfer required.

03

Prepare access

Drill, port or open up locally and set out any containment.

04

Inject or grout

Introduce the material at controlled pressure through planned access points.

05

Check & record

Monitor, proof-test where specified and record the completed works.

PROJECTS RELATED

Projects using Resin Injection & Structural Grouting

See All Projects
Our clients
TECHNICAL QUESTIONS

FAQ'S

What is the difference between resin injection and cementitious grouting?

Injection resins and cementitious grouts have different flow, bond, movement, moisture and strength characteristics. Resin may be selected for structural crack bonding, flexible water control or anchoring. Cementitious grout is commonly used to fill prepared gaps or provide continuous bearing and load transfer. The defect and design determine the material.

Can resin injection waterproof a crack?

Some injection systems are designed to control water, while others are intended for rigid structural bonding. Crack movement, water pressure, substrate condition and the required outcome must be established before selecting a system.

Can void filling avoid demolition?

It can reduce demolition where the surrounding construction remains sound and the void can be accurately defined, accessed, contained and filled. It is not suitable for every void, and targeted opening-up or testing may still be required.

Discuss a Resin Injection & Structural Grouting Project